Rigol DS2000 Series Guide de l'utilisateur Page 140

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 264
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 139
RIGOL 6 To Make Measurements
DS2000 User’s Guide
6-20
Other Parameters
1. Area: the area of the whole waveform within the screen and the unit is
voltage-second. The area meadured above the zero reference (namely the
vertical offset) is positive and the area measured below the zero reference is
negative. The area measured is the algebraic sum of the area of the whole
waveform within the screen.
2. Period Area: the area of the first period of waveform on the screen and
the unit is voltage-second. The area above the zero reference (namely the
vertical offset) is positive and the area below the zero reference is negative. The
area measured is the algeraic sum of the area of the whole period waveform.
Note that when the waveform on the screen is less than a period, the period
area measured is 0.
Vue de la page 139