Rigol DM3064 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Multimètres Rigol DM3064. Rigol DM3064 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - DM3000 Digital Multimeter

RIGOL Programming Guide DM3000 Digital Multimeter Apr. 2010 RIGOL Technologies, Inc.

Page 2

RIGOL Chapter 1 Programming Overview

Page 3 - Guaranty and Declaration

Chapter 1 Programming Overview RIGOL Programming Guide for DM3000 1-5 Commands Introduction To m

Page 5 - Contents

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-1 Chapter 2 Command System In RIGOL DM3000 series digital multimeters commands, al

Page 6

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-2 Common Commands The commands are used to query the basic information of

Page 7

Chapter 2 Command System RIGOL Programming Guid

Page 8 - Programming Introduction

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-4 :FUNCtion Commands The commands are used to enable common measurement func

Page 9 - Symbol Description

Chapter 2 Command System RIGOL Programming Guid

Page 10 - Parameter Type

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-6 Syntax :FUNCtion:FRESistance Function Turns on the 4-wire resistance measurement fu

Page 11 - Commands Introduction

Chapter 2 Command System RIGOL Programming Guid

Page 13 - Chapter 2 Command System

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-8 1. :MEASure? Syntax :MEASure? Function Queries whether the current measurement has

Page 14 - Common Commands

Chapter 2 Command System RIGOL Programming Guid

Page 15 - Programming Guide for DM3000

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-10 9. :MEASure:VOLTage:DC:RATIo:DIGIt Syntax :MEASure:VOLTage:DC:RATIo:DIGIt? :MEASu

Page 16 - :FUNCtion Commands

Chapter 2 Command System RIGOL Programming Guid

Page 17

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-12 secondary screen and the meter is measuring AC voltage. 18. :MEASure:VOLTage:AC

Page 18

Chapter 2 Command System RIGOL Programming Guid

Page 19 - :MEAsure Commands

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-14 The query returns 0, 1, 2 or 3. 26. :MEASure:CURRent:AC:DIGIt Syntax :MEASure:C

Page 20

Chapter 2 Command System RIGOL Programming Guid

Page 21

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-16 Explanation Refer to the “Explanation” in :MEASure:VOLTage:DC:DIGIt. Example Setti

Page 22

Chapter 2 Command System RIGOL Programming Guid

Page 23

RIGOL Programming Guide for DM3000 I Guaranty and Declaration Copyright © 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information

Page 24

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-18 44. :MEASure:PERiod Syntax :MEASure:PERiod {0|1|2|3|4|MIN|MAX|DEF} Function Sets

Page 25

Chapter 2 Command System RIGOL Programming Guid

Page 26

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-20 1 20 nF 2 200 nF 3 2 uF 4 20 uF 5 200 uF MIN 2 nF MAX 200 uF DEF 200 nF Example S

Page 27

Chapter 2 Command System RIGOL Programming Guid

Page 28

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-22 1. :RESOlution:VOLTage:DC Syntax :RESOlution:VOLTage:DC? :RESOlution:VOLTage:DC {

Page 29

Chapter 2 Command System RIGOL Programming Guid

Page 30 - <value>

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-24  The “DEF” is 1. Example Setting the AC voltage measurement the reading resoluti

Page 31

Chapter 2 Command System RIGOL Programming Guid

Page 32

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-26 :SYSTem Commands The commands are used to set the system parameters about the m

Page 33 - :RESOlution Commands

Chapter 2 Command System RIGOL Programming Guid

Page 34

RIGOL

Page 35

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-28 Default DISPLay 7. :SYSTem:CLOCk:DATE Syntax :SYSTem:CLOCk:DATE? :SYSTem:CLOCk:D

Page 36

Chapter 2 Command System RIGOL Programming Guid

Page 37

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-30 17. :SYSTem:TYPE? Syntax :SYSTem:TYPE? Function The query returns the instrum

Page 38 - :SYSTem Commands

Chapter 2 Command System RIGOL Programming Guid

Page 39

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-32 1. :UTILity:INTErface:LAN:DHCP Syntax :UTILity:INTErface:LAN:DHCP? :UTILity:INTEr

Page 40

Chapter 2 Command System RIGOL Programming Guid

Page 41

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-34 Explanation <value> is an integer ranging from 1 to 30. Default 7 9. :UT

Page 42

Chapter 2 Command System RIGOL Programming Guid

Page 43 - :UTILity Commands

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-36 1. :TRIGger:SOURce Syntax :TRIGger:SOURce? :TRIGger:SOURce {AUTO|SINGLE|EXT} Func

Page 44 - <ip_address>

Chapter 2 Command System RIGOL Programming Guid

Page 45

RIGOL

Page 46

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-38 The query returns the pulse width in ms. Explanation Different reading resolutio

Page 47 - :TRIGger Commands

Chapter 2 Command System RIGOL Programming Guid

Page 48

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-40 1. :CALCulate:FUNCtion Syntax :CALCulate:FUNCtion? :CALCulate:FUNCtion {NONE|NULL

Page 49

Chapter 2 Command System RIGOL Programming Guid

Page 50

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-42 9. :CALCulate:DB:STATe Syntax :CALCulate:DB:STATe? :CALCulate:DB:STATe {ON|OFF|1|

Page 51 - :CALCulate Commands

Chapter 2 Command System RIGOL Programming Guid

Page 52

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-44 Frequency 3 - 3.0e+05 3 Hz Period 3.0e-06 - 3.0e-01 3.0e-06 s Ratio ± 1.0e+09 -1.0

Page 53 - <range>

Chapter 2 Command System RIGOL Programming Guid

Page 54

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-46 1. :DATAlog:CONFigure? Syntax :DATAlog:CONFigure? Function The query returns the

Page 55

Chapter 2 Command System RIGOL Programming Guid

Page 57 - :DATAlog Commands

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-48 3 1/m 1/MIN 4 1/10 s 1/10 SEC 5 1/s 1/SEC 6 10/s 10/SEC 7 50/s 50/SEC 8 100/s 100/

Page 58

Chapter 2 Command System RIGOL Programming Guid

Page 59

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-50 :SCAN Commands The commands are used to set the scan parameters for the instrumen

Page 60 - <value2>

Chapter 2 Command System RIGOL Programming Guid

Page 61

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-52 <Range> can be AUTO|0|1|2|3|4|5|6, AUTO denotes using auto range measurement

Page 62 - :SCAN Commands

Chapter 2 Command System RIGOL Programming Guid

Page 64

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-1 Chapter 3 Commands Compatibility The DM3000 series digital multimeter no

Page 65

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-2 Agilent Commands Compatibility The following table lists the commands of A

Page 66

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-3 {<value>|MINimum} CAL

Page 67

Chapter 1 Programming Overview RIGOL Programming Guide for DM3000 1-1 Chapter 1 Programming Overview This chapter guides you how to prop

Page 68

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-4 [,{<resolution>|MIN|MAX|DEF}]] and then configures the meter for 4-wi

Page 69

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-5 FETCh:CURRent[:DC]:PEAK:MINim

Page 70

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-6 [SENSe:]CURRent:AC:NULL:VALue? [{MIN|MAX}] [SENSe:]CURRent:AC:NULL:VALue {&

Page 71

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-7 {<range>|MIN|MAX|DEF} [

Page 72

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-8 {ON|OFF} [SENSe:]FRESistance:NULL:VALue? [{MIN|MAX}] [SENSe:]FRESistance:NU

Page 73

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-9 [,{<resolution>|MIN|MAX

Page 74

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-10 buffer. [SENSe:]MEASure[:VOLTage][:DC]? [{<range>|AUTO|MIN|MAX|D

Page 75

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-11 [{MIN|MAX}] [SENSe:]PERiod:V

Page 76

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-12 {<value>|MIN|MAX} [SENSe:]VOLTage:AC:PEAK:STATe? [SENSe:]VOLTage:AC:

Page 77

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-13 [SENSe:]VOLTage[:DC]:RANGe:A

Page 78

RIGOL Chapter 1 Programming Overview

Page 79

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-14 "<address>" SYSTem:COMMunicate:LAN:HOSTname? [{CURRent|STA

Page 80

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-15 Fluke Commands Compatibility

Page 81 - Fluke Commands Compatibility

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-16 HOLDCLR Exits the Touch Hold function and restores the meter into normal

Page 82

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-17 RATE? Queries the measuremen

Page 84

Index: Command Quick Reference RIGOL Programming Guide for DM3000 1 Index: Command Quick Reference *CLS 2-3 *IDN? 2-3 *RST 2-3 C CMDSet

Page 85

RIGOL Index: Command Quick Reference Programming Guide for DM3000 2 :MEASure:VOLTage:DC:RATIo? 2-9 :MEASure:VOLTage:DC:RATIo:DIGIt 2-10 :MEASure:

Page 86

Index: Command Quick Reference RIGOL Programming Guide for DM3000 3 :SYSTem:DISPlay:CONTrast 2-29 :S

Page 87

Chapter 1 Programming Overview RIGOL Programming Guide for DM3000 1-3 Symbol Description 1. Col

Commentaires sur ces manuels