RIGOL
Programming Guide for DM3058
Function:
The command sets the measuring range of 2-wire resistance.
Parameters:
Name
Type
Range of Values
Default
<range>
discrete
{0|1|2|3|4|5|6}
3
Explanations:
The table 3-5 indicates the parameters and the range.
Table 3-5 The two circuits resistance ranges
Parameter
Range
0
200 Ω
1
2 KΩ
2
20 KΩ
3
200 KΩ
4
1 MΩ
5
10 MΩ
6
100 MΩ
MAX
100 MΩ
MIN
200 Ω
DEF
200 KΩ
Example:
To set the measuring range of 2-wire resistance as 200.0 Ω:
:measure:resistance□MIN or :measure:resistance□0
19. :measure:resistance:range?
Command Format:
:measure:resistance:range?
Function:
The command queries the measuring range of 2-wire resistance.
Return Format:
The query returns the parameter related to current range : 0, 1, 2, 3, 4, 5 or 6