Chapter 2 Basic Waveform Output RIGOL
User’s Guide for DG5000
2-5
To Output Square Waveform
To output a square waveform from CH1 with 20 kHz frequency, 2.5 Vpp amplitude,
500 mV
DC offset, 30% duty cycle and 10 ° start phase. Refer to To Output Sine
Waveformto configure the parameters and output. This section will only talk about
Duty Cycle.
What’s Duty Cycle?
Duty Cycle is defined as the percentage that the high level takes up in the whole
period.
T
t
Duty Cyc=t/T*100%
Set the Duty Cycle
1. Press Square to select square waveform. The key will be illuminated and the
corresponding menus display at the bottom of the screen.
2. Press Duty Cycle to highlight the softkey, and then use the numeric keyboard to
input “30” and select the unit “%” in the pop-up menu.
The duty cycle range is limited by the Freq/Periodsetting.
For frequency lower than or equal to 10 MHz: 20 to 80
For frequency greater than 10 MHz and lower than or equal to 40 MHz: 40
to 60
For frequency greater than 40 MHz: 50
You can also use the knob to modify this parameter.