Rigol DS1000E series Guide de l'utilisateur Page 103

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 162
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 102
RIGOL
© 2008 RIGOL Technologies, Inc.
User’s Guide for DS1000E, DS1000D Series
2-75
Record
Waveform recorder records input waveforms from CH1 and CH2, with a maximum
record length of 1000 frames. This performance can also be activated by the
Pass/Fail test output, which makes this function especially useful to capture
abnormal signals in long term without keeping an eye watching it. This function
contains four modes: OFF, Record, Play back and Storage. More details about the
function please refer to the following introduction.
1. OFF: It will close all record functions.
2. Record: To record waveform by selected time interval till the last frame.
Press UtilityRecordModeRecord to go to the following menu.
Figure 2- 101 Table 2- 64 The Record menu (Page 1/2)
Menu
Settings
Comments
Mode
Record
Play back
Storage
OFF
Select record mode
Select play back mode
Select storage mode
Turn off all recorder functions
Source
CH1
CH2
P/F-OUT
Select record source channel
End Frame
<1-1000>
Set number of record frames
Operate
(Run)
(Stop)
Record stopped, press to
Start recording
Recording, press to stop
Vue de la page 102