Rigol DS1000D Manuel d'utilisateur Page 69

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 166
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 68
RIGOL
© 2008 RIGOL Technologies, Inc.
User’s Guide for DS1000E, DS1000D Series
2-39
Slope Trigger
Slop Trigger Mode: Slope trigger sets the oscilloscope as the positive/negative
slope trigger within the specified time. Press Trigger MENUModeSlope to
display the slope trigger menu as follows.
Figure 2- 45 Table 2- 23 The Slope Trigger Menu (Page 1/2)
Menu
Settings Comments
Source
CH1
CH2
EXT
Set channel 1 as trigger source
Set channel 2 as trigger source
Set EXT. channel as trigger source
When
To select the slope condition
Time
[1]
To set slope time
NOTE
[1]
:
Slope time can be set from 20ns to 10s. When a signal meets the trigger condition,
The oscilloscope will execute the acquisition.
Figure 2- 46 Table 2- 24 The Slope Trigger Menu (Page2/2)
Menu
Settings Comments
Vertical
[2]
Select the
level that can be adjusted
by
Sweep
Auto
Normal
Single
Acquire waveform even when no
trigger condition is met.
Acquire waveform when trigger
condition is met.
When trigger condition is met, acquire
one waveform and then stop
Set Up To go to set up menu. See table 2-38
NOTE
[2]
:
You can adjust LEVEL A/ LEVEL B or both simultaneous by turning the
knob.