User‟s Guide for DS1000CA Series
2-8
2. Set up the channel bandwidth limit
Take CH1 for an example, input a signal containing high frequency component.
Press CH1BW LimitOFF, to set up bandwidth limit to “OFF” status. The
oscilloscope is set to full bandwidth and passing the high frequency component
in the signal.
Figure 2-6 Turn off the BW limit
Press CH1BW LimitON, to set up bandwidth limit to “ON” status. It will
reject the frequency component higher than 20MHz.
Figure 2-7 Turn on the BW limit
Turn Off the
BW Limit
Mark of
BW Limit
20M BW Limit