RIGOL
© Copyright RIGOL Technologies, Inc. 2007. 2-51
User’s Guide for DS1000 Series
Duration Trigger (Mixed Signal Oscilloscope)
Trigger in appointed time when code terms are satisfied.
Figure 2-60 Table 2-36 (Page One)
Menu Settings Comments
Select D15-D0
Choose digital channel for Duration Trigger
Code
H
L
X
High
Low
Ignore
Qualifier
<
>
=
Set time limit terms
Figure 2-61 Table 2-37 (Page Two)
Menu Settings Comments
Time
<
Time
Setting
>
Set duration and limit symbol time
Sweep
Auto
Normal
Single
Acquire waveform even no trigger occurred
Acquire waveform when trigger occurred
When trigger occurs, acquire one waveform
and then stop
Set Up To go to set up menu, see table 2-40