RIGOL 13 System Function Setting
DS2000 User’s Guide
13-12
Aux Output
Users can set the type of the signal output from the [Trigger Out] connector at the
rear panel.
Press Utility AuxOutput to select the desired output type.
1. TrigOut
After this type is selected, the oscilloscope outputs a signal that can reflect the
current capture rate of the oscilloscope at each trigger.
2. PassFail
After this type is selected, the oscilloscope will output a pulse signal when failed
waveforms are detected. This signal can be connected to other control systems
to conveniently view the test results.