Vue de la page 89
RIGOL Chapter 2 Command System
2-76 DS1000Z Programming Guide
:SYSTem Commands
:SYSTem 命令用于设置声音, 语言等系统相关的设置.
Command List:
:SYSTem:AUToscale
:SYSTem:BEEPer
:SYSTem:ERRor[:NEXT]?
:SYSTem:GPIB
:SYSTem:LANGuage
:SYSTem:LOCKed
:SYSTem:PON
:SYSTem:OPTion:INSTall
:SYSTem:OPTion:UNINSTall
:SYSTem:AUToscale
Syntax :SYSTem:AUToscale <bool>
:SYSTem:AUToscale?
Description
Enable or disable the AUTO key at the front panel, or query the status of the AUTO key.
Parameter
Name
Type
Range
Default
<bool>
Bool
{{0|OFF}|{1|ON}}
1|ON
Explanation
Users can disable the AUTO key by sending this command or pressing Utility
Auto Options Lock and enable it only by sending this command.
After the AUTO key is disabled, Auto Scale operation is invalid. The :AUToscale
command will be invalid.
Return
Format
The query returns 0 or 1.
Example
:SYSTem:AUToscale ON
:SYSTem:BEEPer
Syntax :SYSTem:BEEPer <bool>
:SYSTem:BEEPer?
Description
Enable or disable the beeper, or query the status of the beeper.
Parameter
Name
Type
Range
Default
<bool>
Bool
{{0|OFF}|{1|ON}}
0|OFF
Return
Format
The query returns 0 or 1.
Example
:SYSTem:BEEPer ON